Testing Excellence

What Is an Anchor Pull Test?

The Anchor Pull Test is a critical field verification procedure required by the NYC Department of Buildings for post-installed anchor installations. Under Chapter 17 of the NYC Building Code (referencing IBC Section 1704 and ACI 318), mechanical and adhesive anchors used in structural applications must demonstrate adequate capacity through in-situ testing before the installation can be approved as part of the special inspection process.

Our certified testing verifies that anchor bolts, post-installed fasteners, and industrial fixtures can safely support the specified design loads without failure or displacement. This verification is essential for DOB compliance and is typically documented as part of the TR8 testing record for the project. Common applications include scaffold anchors, sidewalk bridge supports, facade restoration anchoring systems, parapet securing anchors, and mechanical equipment supports.

Every test is conducted using calibrated equipment with documented load application protocols. Our certified reports include load-displacement data, pass/fail determinations referenced to design requirements, and professional engineering certification — providing the documentation required for DOB closeout and project signoff.

Anchor pull testing
Safety
Verified Through Testing
Our Process

DOB-Certified Anchor Pull Testing Protocol

Our testing procedures follow NYC Building Code requirements and referenced ASTM standards to ensure accurate results, repeatable methodology, and documentation that satisfies DOB compliance requirements for TR8 testing records.

Pre-Test Review

Review of installation specifications, design requirements, and applicable codes.

Load Application

Controlled application of test loads to verify anchor performance under specified conditions.

Performance Monitoring

Careful observation for any signs of failure, movement, or inadequate performance.

Certified Reporting

Detailed documentation of test results with professional engineering certification.

Construction safety
Critical Verification

Ensuring Structural Safety

Verifies anchor capacity per IBC and ACI 318 requirements
Identifies potential failures before they become safety hazards
Provides documented proof of NYC Building Code compliance
Protects building owners from liability and DOB violations
Ensures long-term structural integrity of connections
Required for DOB approval and TR1 signoff on critical installations
Applications

Common Testing Applications

Scaffold anchor installations
Sidewalk bridge support anchors
Facade anchoring systems
Parapet securing anchors
Structural support anchors
Safety line anchorage points
Mechanical equipment anchors
Post-installed anchoring systems
Renovation and retrofit anchors